Home » Products » Health & Personal Care » Medical & Homeopathic Supplies » Medical Diagnostic Instrument
Anti-HCV CLIA test kit
Delivery term:The date of payment from buyers deliver within days- Price:
Negotiable
- minimum:
- Total supply:
- Delivery term:
The date of payment from buyers deliver within days
- seat:
Beijing
- Validity to:
Long-term effective
- Last update:
2017-12-09 07:20
- Browse the number:
67
Company Profile
- Ningbo Newcare Import & Export Co. Ltd
-
Contact:
egens-bio(Mr.)
-
Email:

-
Telephone:

-
Area:
Beijing
-
Address:
Room 1605, Aux Central Building, No. 757 Rili Middle Road, Yinzhou District, Ningbo, Zhejiang, China (315100)
- Website: http://egens-bio.lvxiangruaa.com/
By certification [File Integrity]
Product details
Model Number: Anti-HCV CLIA01
Brand Name: Egens
Key Specifications/Special Features:
ThisAnti-HCVCLIAisaqualitativemicroplatechemiluminescenceassayforthe invitrodetectionofantibodiestoHepatitisCVirus (HCV)inhumanserumorplasma.Itisintendedforscreeningofblooddonorsand diagnosingpatientsrelatedtoinfectionwithHepatitisCvirus.ASSAY PROCEDUREPrepare Reagents: Dilute 1 volume of Concentrated Washing Buffer (20×) with 19 volumes of distilled water, mix well.Add Samples: Open the foil pouch and remove the Microplate. Set up 1 well as Blank, 2 wells as standard, 1 well as negative control, 1 well as positive control. After dispensing 100μL of Sample Diluent, dispense 25μL of sample or standard or negative control or positive control to the respective wells. Gently vibrating the plate.Incubate: Cover the Microplate with plate cover and incubate the Microplate in a thermostat-controlled water-bath or microplate incubator at 37℃ for 30 minutes.Wash: Wash the Microplate for 5 times. Fill the wells with above 350μL of the diluted Washing Buffer, Soak for above 30 seconds, then aspirate again for each time. Make sure that the rest volume is minimal by tapping plate at absorbent paper.Add Conjugate: Add 100μL of conjugate to each well (except the blank well).Incubate: Cover the Microplate and incubate the plate at 37℃ for 30 minutes.Wash the Plate: Repeat the wash procedure as in step 4.Add Substrate: Add 50μL of Substrate Solution A and 50μL of Substrate Solution B to each well, Vibrate the Microplate. Cover and incubate the Microplate in the dark at room temperature (18-24℃) for 5-10 minutes.Read the RLU value by a microplate chemiluminescence immunoassay analyzer.
Shipping Information:
- FOB Port: Shanghai
- Lead Time: 15 - 30 days
Main Export Markets:
- Asia
- Australasia
- Central/South America
- Eastern Europe
- Mid East/Africa
- North America
- Western Europe
New Products
-
High Temperature Heat Pump
price: Negotiable
-
R32 Inverter Heat Pump
price: Negotiable
-
Domestic Heat Pump Water Heater
price: Negotiable
-
Commercial Air Source Heat Pump
price: Negotiable
-
Dc Heat Pump
price: Negotiable
-
Used CAT 336D Crawler Excavator
price: Negotiable










